Cast 316G Stainless Steel Marine Louvre Vent 98 × 98 mm for 76 mm Cutout SA30580
The 30580 square louvre vent provides a highly polished cast stainless steel face for an airflow opening. It has seven louvres and measures 98 x 98 x 10 mm. The 316G cast construction distinguishes it from a thin stamped vent, while the polished finish coordinates with other visible stainless fittings.
A 76 mm diameter cutout is specified for this size. Where a hose connection is needed behind the vent, matching nylon elbow tail 30584 provides a 76 mm right-angle connection. That elbow is a separate component, so select the vent and any required connector as individual parts of the ventilation layout.
Features and specifications
- Cast 316G stainless steel.
- Highly polished finish.
- Seven-louvre square face.
- Matching optional hose elbow: 30584, 76 mm tail.
- Louvres: 7.
- Dimensions W x H x D (mm): 98 x 98 x 10.
- Cut Out Ø (mm): 76.
- Mount Screws: 4 mm countersunk.
Choosing and fitting
Check both the 98 mm square footprint and the 76 mm opening against the proposed panel. The external face needs enough flat surrounding material for its mounting screws, while the cutout needs to remain clear of structure behind the surface. Compare actual hole positions before reusing an existing mounting pattern.
If fitting elbow 30584, allow space for its body and for the hose beyond the turn. Confirm that the hose can follow the intended route without being crushed or pushed against another fitting. The elbow flange sits behind the vent, so assess fastener length for the whole assembly rather than the face alone.
Use the specified 4 mm countersunk screw format with fixings appropriate for the supporting structure. Position the vent where the louvres can remain unobstructed and accessible for cleaning. The opening size and louvre count are physical specifications, not a stated airflow capacity for the complete installation.
Care and use
Rinse salt deposits from the stainless face and dry it when practical. Use a non-abrasive cleaner suitable for stainless steel, and clear dirt from between the louvres. Periodically inspect the fixing points and any hose connection behind the vent, especially after moving nearby equipment or servicing the compartment.