#   Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing   189302

   [![Twitter](https://www.rhsboating.com.au/media/com_hikashop/images/icons/twitter_icon.png)Twitter](https://twitter.com/intent/tweet?url=https%3A%2F%2Fwww.rhsboating.com.au%2Fcategories%2Frule-a-matic-float-switch-boat-plumbing-boat-pumps-plumbing.html)[![Pinterest](https://www.rhsboating.com.au/media/com_hikashop/images/icons/pintinterest_icon.png)Pinterest](http://pinterest.com/pin/create/button/?url=https%3A%2F%2Fwww.rhsboating.com.au%2Fcategories%2Frule-a-matic-float-switch-boat-plumbing-boat-pumps-plumbing.html&media=https://www.rhsboating.com.au/images/com_hikashop/upload/thumbnails/100x100/189302.jpg)[![Facebook](https://www.rhsboating.com.au/media/com_hikashop/images/icons/facebook_icon.png)Facebook](https://www.facebook.com/sharer/sharer.php?u=https%3A%2F%2Fwww.rhsboating.com.au%2Fcategories%2Frule-a-matic-float-switch-boat-plumbing-boat-pumps-plumbing.html&display=page)[![Linkedin](https://www.rhsboating.com.au/media/com_hikashop/images/icons/linkedin_icon.png)Linkedin](https://www.linkedin.com/sharing/share-offsite/?url=https%3A%2F%2Fwww.rhsboating.com.au%2Fcategories%2Frule-a-matic-float-switch-boat-plumbing-boat-pumps-plumbing.html)

     [Previous](#)[Previous](#)[Previous](#) [![189302](https://www.rhsboating.com.au/images/com_hikashop/upload/thumbnails/300x300/189302.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")](https://www.rhsboating.com.au/images/com_hikashop/upload/189302.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")

 [Next](#)[Next](#)[Next](#)

   [![189302](https://www.rhsboating.com.au/images/com_hikashop/upload/thumbnails/300x300/189302.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")](https://www.rhsboating.com.au/images/com_hikashop/upload/189302.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")[![189302-1](https://www.rhsboating.com.au/images/com_hikashop/upload/thumbnails/300x300/chatgpt_image_sep_24_2026_09_02_48_am.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")](https://www.rhsboating.com.au/images/com_hikashop/upload/chatgpt_image_sep_24_2026_09_02_48_am.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")[![RHS-Boating-Marine-Sydney](https://www.rhsboating.com.au/images/com_hikashop/upload/thumbnails/300x300/RHS-Boating-Marine-Sydney.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")](https://www.rhsboating.com.au/images/com_hikashop/upload/RHS-Boating-Marine-Sydney.jpg "Rule-A-Matic Float Switch – Boat Plumbing – Boat Pumps & Plumbing")

    $72.62  each

            Brand: [RHS Boating & Marine – Boat Parts, Marine Accessories & Boating Supplies](https://www.rhsboating.com.au/brands-listing/category/rhs-boating-marine-boat-parts-marine-accessories-boating-supplies.html)

 [+](#)

 [–](#)

 The add to cart button will appear once you select the values above

    ### Rule-A-Matic Float Switch

Add water-level control to a compatible bilge pump with Rule-A-Matic Float Switch. Product 189302 is rated for 12 or 24 V systems and a maximum pump load of 14 A.

A sealed float mechanism controls automatic bilge operation.

Excludes Rule 3700 and 4000 12 V pump models.

Check both voltage and current before selecting a switch. A pump capacity figure alone does not establish electrical compatibility, and the float or sensor needs the clearance required by its installation instructions.

### Choosing and using this product

Select the pump or service component for the actual job: bilge drainage, fresh water, washdown, livewell circulation and waste handling place different demands on a system. Match the stated application first, then compare the power supply, connections and operating details for this exact version.

For a service part, identify the existing pump model before ordering. A motor cartridge, switch, strainer or valve renews only its stated part of the assembly. Check adjacent hoses and connections at the same time so an unrelated problem is not mistaken for a failed replacement component.

Compare the package contents with the complete installation you are planning. Pump-only listings and kits can differ in switches, fittings and hoses. Listing the required components before ordering helps you select the appropriate package and avoids treating an illustrated accessory as an included part.

A flow figure alone does not describe the complete installation. Hose routing, outlet height and the rest of the plumbing can affect the delivered result. Use the relevant pump guidance when sizing the system rather than treating a catalogue flow figure as a guaranteed output at every outlet.

Allow practical access for inspection and servicing when deciding where the equipment will sit. Check the electrical and plumbing connections against the product instructions, and verify the finished system under its intended operating conditions. Keep the model reference accessible for later maintenance.

### Product details

- Voltage: 12 or 24 V
- Maximum current: 14 A
- Product code: 189302
